J2121A High Power Line Injector 100Hz - 1MHz

※交期請來信/電詢問。
※可開立發票及統編。

What's included :
1. J2121A High Power Line Injector
2. 1 ohm Calibration Fixture
3. J2171A 200mA Low Noise Power Supply
4. User manual
5. 1 Year Warranty
NT$96,275
商品編號:
供貨狀況: 尚有庫存

此商品參與的優惠活動

加入最愛
商品介紹
 
 
 
 
J2121A 特色:
 
。最大400V/20A -支持高功率270V軍用和衛星總線應用
 
。100Hz~1MH頻寬
 
。穩壓輸入輸出電壓降500mV
 
。隔離電流檢測監視器輸出
 
。內建風扇冷卻
 
。配合高PSRR低噪音穩壓器(J2171A)使用
 
 
J2121A 應用:
 
 
 
。電源抑制比(PSRR)測量
 
。電感直流偏置測量(最高20A)
 
。DC-DC轉換器輸入阻抗測試
 
 
 
J2121A - Product Information
 
 
 
 
 

While the injection transformer used for Bode plots is a very wideband transformer, it is not useful for measuring ripple rejection (PSRR) of a power supply or even an opamp. Doing so could permanently damage the transformer. This is because the attributes that make the injection transformer perform so well also result in a transformer that is intolerant of DC current. Even very small DC currents (5mA or less) can greatly reduce the signal capacity or even totally saturate the transformer. For this reason, the Picotest line injector (J2121A) is another essential test adapter for power supply testing.

 

The J2121A is especially suited to high power applications such as those associated with military and satellite busses. It can be used with input bus voltages up to 400V and supply up to 20A at 1MHz. The line injector allows the input DC supply voltage to be modulated by the network analyzer source signal (oscillator). The J2121A line injector output is DC regulated and provides a fixed voltage drop of 750mV from the input bus voltage fed into the injector in addition to the AC modulation signal.

 

The J2121A can be connected to the power supply input under test and, depending on the test probe connection points, can be used to measure either PSRR or the power supply’s input impedance The line injector can also be used to measure the impedance/inductance of an inductor under bias.

 

While a current probe can be used as part of a test setup, the J2121A includes a current sense monitor output that can be connected to the VNA.

 

The J2121A comes with the J2171A power supply and connecting cable, used to power it, and a 1-ohm calibration fixture.

 
 
  J2121A - Detailed Specifications:
 
 
Specifications
Characteristic Typical
Maximum DC Input Voltage 400VDC
Maximum Continuous Current 20A
Typical Input-Output Voltage Drop 0.70VDC
Modulation Input Impedance 50ohms
Output Signal Bandwidth 100 ~ 1MHz
Current Monitor Bandwidth (THRU CAL) DC ~ 1MHz
Current Monitor Scale(AC) 100mV/A
Current Monitor Termination Impedance 50 or 1Mohms
Max Current Monitor DC Offset 100mV
Recommended Injection Signal 6dBm
Maximum Altitude 6000 Ft
 
 
規格說明
運送方式
已加入購物車
已更新購物車
網路異常,請重新整理